FEATURES
- 1 Guard-Channel Spacing
- Full-Band Tunability
- Temperature Stabilization
- DC-Short
- Modular Connector System
- Modular Frame System
- 10-Year Warranty
OPTIONS
- Heat Sinks
- Forced Air Cooling
- Liquid Cooling
LINKS
- Combiners Coding
- Balanced
- No-Mask-Combiner
- Chain-Combination
DM4E80C |
DM4E110C |
|||||
No. of Poles / Cavity Size | 4-Pole / 80 mm | 4-Pole / 110 mm | ||||
Modular Connector System | 1x PC32 2x PC64 | 1x PC32 2x PC64 | ||||
Max RMS Output Power | 7.0 kW | 7.0 kW | ||||
Max RMS Input Power Default with Heat Sinks |
DVB-T 1.9 kW 2.4 kW |
ATSC 1.4 kW 1.8 kW |
ISDB-T 1.4 kW 1.8 kW |
DVB-T 4.25 kW 5. kW |
ATSC 3.0 kW 4.0 kW |
ISDB-T 3.0 kW 4.0 kW |
DF4E140C |
DF4E200C |
|||||
No. of Poles / Cavity Size | 4-Pole / 140 mm | 4-Pole / 200 mm | ||||
Modular Connector System | 3x PC100 | 3x PC130 | ||||
Max RMS Output Power | 21.0 kW | 45.0 kW | ||||
Max RMS Input Power Default with Heat Sinks with Liquid Cooling with Forced Cooling |
DVB-T 7.5 kW 9.5 kW 19.0 kW 25.0 kW |
ATSC 6.0 kW 7.5 kW 15.0 kW 20.0 kW |
ISDB-T 6.0 kW 7.5 kW 15.0 kW 20.0 kW |
DVB-T 17.0 kW 22.0 kW 42.5 kW 42.5 kW |
ATSC 13.0 kW 16.0 kW 32.5 kW 32.5 kW |
ISDB-T 13.0 kW 16.0 kW 32.5 kW 32.5 kW |